INSTALLATION AND
OPERATING INSTRUCTIONS
REFRIGERATOR FOR LP-GAS AND ELECTRIC OPERATION
NDA1402
USA Corporate Office CANADA
Service Office 2320 Industrial Parkway Elkhart, IN 46515 Dometic Corporation
Dometic Corporation 46 Zatonski, Unit 3
2320 Industrial Pkwy. Brantford, ON N3T 5L8
Elkhart, IN 46516 For Service Center Assistance CANADA
Phone: 574-294-2511 Call: 800-544-4881 Phone: 519-720-9578
Form No. 825124300 MO-FO 0511 7/05 (French 3309980.005)
©2005 Dometic Corporation Lagrange, IN 46761
®
®
Contents:
Page
Installation 5
Operating Instructions 9
Ice dispenser 15
Ice maker 16
Maintenance & Service 17
FOR YOUR SAFETY
If you smell gas:
1. Open windows.
2. Don’t touch electrical switches.
3. Extinguish any open flame.
4. Immediately call your gas supplier.
FOR YOUR SAFETY
Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
WARNING: Improper installation,
adjustment, alteration, service or
maintenance can cause injury or
property damage. Refer to this
manual. For assistance or additional
information consult a qualified
installer, service agency or the gas
supplier.
Pour votre sécurité
Si vous sentez une odeur de gaz:
1. Ouvrez les fenêtres.
2. Ne touchez à aucun interrupteur.
3. Éteignez toute flamme nue.
4. Avertissez immédiatement votre fournis-
seur de gaz.
Pour votre sécurité
Ne pas entreposer ni utiliser de l’essence ni
d’autres vapeurs ou liquides inflammables à
proximité de cet appareil ou de tout autre
appareil.
Avertissement: Une installation, un réglage,
une modification, une réparation ou un
entretien non conforme aux normes peut
entraîner des blessures ou des dommages
matériels. Lisez attentivement le mode d’em-
ploi fourni avec l’appareil. Pour obtenir de
l’aide ou des renseignements supplémentai-
res, consultez un installateur ou un service
d’entretien qualifié ou le fournisseur de gaz.
autodefrost
Vue de la page 0
1 2 3 4 5 6 ... 23 24

Résumé du contenu

Page 1 - OPERATING INSTRUCTIONS

INSTALLATION ANDOPERATING INSTRUCTIONSREFRIGERATOR FOR LP-GAS AND ELECTRIC OPERATIONNDA1402USA Corporate Office CANADAService Office 2320 Industrial P

Page 2 - GENERAL INSTRUCTION

11Status messageStatus message Message displayed Steady Alternating betweendisplay temperatures andmessageDefrosting is just now performed ”dE Fr” XTh

Page 3 - FREEZER FRIDGE

12Manual defrostIf desired this refrigerator can be set to defrost manual at any time.Usually a defrost cycle takes about 1 hour but is depending on t

Page 4 - INSTALLATION

13HOW TO USE THE REFRIGERATORFOOD STORAGE COMPARTMENTThe food storage compartment is completely closed andunventilated, which is necessary to maintain

Page 5 - ENCLOSURE

14ELECTRIC EQUIPMENTHEATERSThe heat necessary for the operation of an absorptioncooling unit is supplied by an electric heater mounted ina pocket of t

Page 6 - SHUT OFF

15Automatic Ice DispenserThe ice dispenser on the freezer door conveniently dispenses ice.TO OPERATE THE DISPENSERSelect the ice option desired, CUBES

Page 7 - LOWER VENT CUTOUT

16ICE MAKERGENERAL INSTRUCTIONS ANDOPERATION1. The refrigerator must be connected to 120 volts ACbefore the ice maker can operate. The water valvesupp

Page 8 - INSTRUCTIONS

176. Connect compressed air onto the inlet fitting of thewater solenoid valve. See FIG. 14. Apply AC powerto the solenoid valve by forcing the ice mak

Page 9 - START UP INSTRUCTIONS

18D. Inspect the flue baffle. It should be reasonably cleanand free of soot. Heavy soot formation indicates im-proper functioning of the burner. The f

Page 10 - Status message

193. REPLACING A HALOGEN LAMPTROUBLESHOOTINGThe Refrigerator Does Not Cool ProperlyA. Burner jet clogged.Clean. (See section Maintenance & Service

Page 11 - Call For Service

20CERTIFIED VENT SYSTEM KITSREFRIGERATOR KITMODEL NO. COMPONENTS PART NO.NDA 1402 5A Roof Base 3103633.XXX*Roof Cover 3103634.XXX*Lower Side Vent 3109

Page 12 - HOW TO USE THE REFRIGERATOR

3NDA 1402Rear view equipment used for text referenceGENERAL INSTRUCTIONThis appliance is designed for storage of foods andstorage of frozen foods and

Page 13 - ELECTRIC EQUIPMENT

21Number Instruction Note00 — —01 LED panel check All LED segments ON02 Battery voltage check ”12” → in range between 8,5 - 18 V DC.“Lo” or “hl” → out

Page 14 - Automatic Ice Dispenser

22Put a screwdriver into the slot of the shelf lock.Turn the screwdriver counterclockwise.Remove the shelf locks from the wire shelf.Slide the wire sh

Page 15 - ICE MAKER

23Fuse Type of component3A A, B, C, E, G, H, P, R7.5A S, T3A W, (Optional ice maker heat-kit)7.5A X5A ZFUSESRefer to wiring diagram.Fuses from left to

Page 17 - GAS EQUIPMENT ASSEMBLY

Patents pendingU.S. 10/619,675U.S. 10/620,177U.S. 10/758,174U.S. 10/758,175U.S. 10/760,564U.S. 10/760,565This product is manufactured under license of

Page 18 - TROUBLESHOOTING

4Refrigerator control panelFIG. 212 3 4LEGEND 2-WAY ModelPanel Controls:1. Main Power ON/OFF key2. AUTO/STORE key/ Combined energy mode selection and

Page 19 - CERTIFIED VENT SYSTEM KITS

5INSTALLATIONVENTILATIONThe installation shall be made in such a manner as toseparate the combustion system from the living spaceof the mobile home or

Page 20 - SERVICE MODE

6INSTALLING REFRIGERATOR INENCLOSURESecuring the RefrigeratorAfter the refrigerator is put in place, (ensuring a com-bustion seal at the front frame),

Page 21 - Positioning of shelves

7Step 2: Two screws installed in the top frame.Open the doors and fasten the refrigerator with twoscrews through the holes underneath the top decorati

Page 22

8CERTIFIED INSTALLATIONCertified installations require one roof vent and one lowerside vent.For “Certified Vent System Kits” see page 20.For further i

Page 23 - MO-FO 0511

9OPERATINGINSTRUCTIONSIMPORTANCE OF LEVELING AREFRIGERATORIn an absorption refrigerator system, ammonia is lique-fied in the finned condenser coil at

Page 24

10START UP INSTRUCTIONS1. Press the main power ON/OFF key. If the real time clock has to be set the LED panel will show flashing horizon-tal bars ” --