An opening toward the outside at floor level in the refrigera-
tor compartment has to be provided for ventilation of heavier-
than-air fuel gases. The lower vent of the recommended kits is
provided with proper size openings. The flow of combustion and
ventilating air must not be obstructed.
The lower side vent is fitted with a panel, which provides an ad-
equate access opening for ready serviceability of the burner and
control manifold of the refrigerator. This should be centered on
the back of the refrigerator.
This appliance is certified under the latest edition of ANSI Z21.19•CSA 1.4 Refrigerators using gas fuel. The installation
must conform with local codes, or in absence of local codes, the following standards as applicable.
In the U.S. the installation must conform with:
National Fuel Gas Code, ANSI Z223.1/NFPA 54
(latest edition).
Recreational Vehicles Code, ANSI A119.2 (latest edition).
Manufactured Home Construction and Safety Standard, Title
24 CFR, Part 3280.
If an external electrical source is utilized, the refrigerator, when
installed, must be electrically grounded in accordance with
local codes or, in the absence of local codes, the National Elec-
trical Code, ANSI/NFPA 70 - (latest edition).
In CANADA, the installation must conform with:
Natural Gas and Propane Installation Code, CSA B149.1
CSA Z240 RV Series, Recreational Vehicles.
Current CSA Z240.4, Gas-equipped Recreational Vehicles
and Mobile Housing.
If an external electrical source is utilized, the refrigerator,
when installed, must be electrically grounded in accordance
with local codes or, in the absence of local codes, the Canadian
Electrical Code, CSA C22.1, Parts I and II - (latest edition).
CERTIFICATION AND CODE REQUIREMENTS
GENERAL INFORMATION
Provide necessary air circulation over the cooling unit. Open-
ings for air supply or for venting of combustion products shall
have a minimum dimension of not less than 1/4 inch.
Certified installations require one roof vent and one lower side
vent. Proper installation requires one lower fresh air intake
and one upper exhaust vent. The ventilation kits shown in this
manual have been certified for use with RM1350. The ventila-
tion kits must be installed and used without modification.
Side vent cutout
CERTIFIED VENT SYSTEM KITS
Kit
no.
Components Part no.
5A Roof Base
Roof Cover
Side Vent
3103633.XXX* or 3310893.XXX*
3103634.XXX* or 3310894.XXX*
3109349.XXX*
* Fill in “XXX” with color code numbers. For color codes, contact
your supplier.
VENTILATION REQUIREMENTS
It is of especially importance that the airflow
around the burner housing, the boiler insula-
tion and the flow of combustion gases must not
be obstructed. Items placed in the vicinity of the
refrigerator compartment accordingly must be
secured away from the refrigerator tubing and
flue.
CAUTION